LEDSMART+ Timers Installations and Setup functions - Pierlite Australia

LEDSMART+ ™ Timers
Installation and setup functions

LEDSMART+ PUSH BUTTON MINUTE TIMER

If the timer has been powered up for LESS THAN 15 MINUTES see A1 below.
If the timer has been powered up for MORE THAN 15 MINUTES see A2 below.

Once in Setup Mode, options are selected by a series of ‘clicks’ of the push button. Each ‘click’ should be within 1 second of the previous click.

Step 1

Press and hold the button for 10 seconds

Note: Connected lights will dim up or down, this is normal

Step 2

The white LED Indicators will blink ON/OFF twice per second.  This indicates that the timer is now in Setup Mode

Note: If more than one LEDsmart+ device is connected in parallel, all these devices will now enter setup mode. The blink ON/OFF will also be see on all other LEDsmart+ devices connected in parallel

In the unlikely event that other LEDsmart+ devices connected in parallel do not enter setup, exit and try again.

Step 3

The timer is ready for the settings to be adjusted as required.  Go to the relevant setup function instructions

Step 1

Press and hold the button for 30 seconds

Note: This resets the Setup Entry time back to 10 seconds (for the next 30 minutes)

Note: Connected lights will dim up or down, this is normal

Step 2

The white LED Indicators will blink ON/OFF twice per second.  This indicates that the timer is now in Setup Mode

Note: If more than one LEDsmart+ device is connected in parallel, all these devices will now enter setup mode. The blink ON/OFF will also be see on all other LEDsmart+ devices connected in parallel

In the unlikely event that other LEDsmart+ devices connected in parallel do not enter setup, exit and try again.

Step 3

The timer is ready for the settings to be adjusted as required.  Go to the relevant setup function instructions

The Minutes timer allows a timeout duration of between 1 to 30 minutes in increments of 1 minute.
Out of the box (factory defaults), the time out interval is set to 15 minutes.
To change the time out interval from the default 15 minutes, follow the steps below.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button twice

Step 3

LED will blink 2 times
Note: To cancel/exit do nothing for 30 seconds

Step 4

To set the time out interval, push and hold the button and count the number of blinks. Each blink of the indicator adds 1 minute to the minute timer

Step 5

When the number of blinks counted equals the number of minutes required, release the button
The time out interval is saved and setup will exit automatically
Note
– During normal use the indicator will blink when the timer is turned on to indicate it is in time out mode
– Trying to select a time interval of 0 will result in setting 1 minute timeout
– The timeout period on Minute Timers connected in parallel need to be set individually. The same timeout is not automatically set across units

The maximum brightness level provided by the timer can be set to suit customer requirements.
Note that when lamps are near to full brightness, it is difficult to see changes in dimming level. Therefore, when setting up maximum brightness, it is recommended that the lamp is slowly dimmed up to a point where no further changes in brightness can be seen, and the maximum level set at this point.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button three times

Step 3

LED will blink 3 times

Note: To cancel/exit do nothing for 30 seconds

Note: If more than one dimmer is connected to the same load, all dimmers connected to this load will now blink 3 times

Step 4 

Push the button to achieve the required maximum brightness level

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

In the unlikely event that other LEDsmart+ devices connected in parallel do not enter setup, exit and try again.

The advanced timer mode provides an optional advanced warning to the user that the lights will shortly turn off automatically.
When the advance timer is enabled, at time out the lights are dimmed to 50% over a 4 second period and are held at this 50% level for 5 minutes. After this 5 minutes, the lights are turned off automatically.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button four times

Step 3

The LED Indicator will blink 4 times
Note: To cancel/exit do nothing for 30 seconds

Step 4

To enable the advanced timer mode
Push and hold the button until the lamps(s) turn ON

To disable the advanced timer mode
Push and hold the button until the lamps(s) turn OFF (default)

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

Note that during this Advanced Timer 5 minute warning period:
– The LED indicators will blink at a faster rate
– A tap of the push button will restore the load to 100% ON and the timer will restart
– A long press of the push button will turn the load OFF.

When the timer is switched off, the white LED indicators in the timer can be set to glow or turn off.
By Default, the white LED indicators are set to glow when the timer is turned off.
To set the LED indicators to turn off when the timer is off, follow the steps below.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button five times

Step 3

LED will blink 5 times

Note: To cancel/exit do nothing for 30 seconds

Step 4

To set Indicator to glow on when timer is off
Push the button until the lamp(s) turns ON

To set Indicator to turn off when timer is off
Push the button until the lamp(s) turns OFF

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

If required, this minute timer can be converted to a standard LEDsmart hour timer, with a time out settable between ¼ hour and 7½ hours, in ¼ hour increments.
To convert to an hour timer, follow the steps below.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button six times

Step 3

LED will blink 6 times

Note: To cancel/exit do nothing for 30 seconds

Step 4

To change operation to hour timer mode

Push and hold the button until the lamps(s) turn ON

To change operation to minute timer mode (Set minute timer mode)

Push and hold the button until the lamps(s) turn OFF (default)

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

Step 1

Enter into the dimmer Setup Mode – See PART A

Step 2

Click the push button 8 times

Step 3

LED will blink 8 times

a.  If the MultiMate™ function is currently Disabled, lamp(s) connected to the dimmer will now turn OFF

b.  If the MultiMate™ function is currently Enabled, lamps(s) connected to the dimmer will now turn ON

Note: To cancel/exit do nothing for 30 seconds

Step 4

To Enable MultiMate™ (Default) adjust the dial Clockwise or push-and-hold the button until the lamp(s) turns ON

To Disable MultiMate™ adjust the dial Anti-clockwise or push-and-hold the button until the lamp(s) turns OFF

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

Step 1

Enter into the dimmer Setup Mode – See PART A

Step 2

Click the dimmer rotary shaft ten times

Step 3

The dimmer will automatically exit Setup Mode once reset

LEDSMART+ PUSH BUTTON
HOUR TIMER

If the dimmer has been powered up for LESS THAN 15 MINUTES see A1 below.
If the dimmer has been powered up for MORE THAN 15 MINUTES see A2 below.

Once in Setup Mode, options are selected by a series of ‘clicks’ of the dimmer push button. Each ‘click’ should be within 1 second of the previous click.

Step 1

Press and hold the button for 10 seconds

Note: Connected lights will dim up or down, this is normal

Step 2

The white LED Indicators will blink ON/OFF twice per second.  This indicates that the timer is now in Setup Mode

Note: If more than one LEDsmart+ device is connected in parallel, all these devices will now enter setup mode. The blink ON/OFF will also be see on all other LEDsmart+ devices connected in parallel

In the unlikely event that other LEDsmart+ devices connected in parallel do not enter setup, exit and try again.

Step 3

The timer is ready for the settings to be adjusted as required.  Go to the relevant setup function instructions

Step 1

Press and hold the button for 30 seconds

Note: This resets the Setup Entry time back to 10 seconds (for the next 30 minutes)

Note: Connected lights will dim up or down, this is normal

Step 2

The white LED Indicators will blink ON/OFF twice per second.  This indicates that the timer is now in Setup Mode

Note: If more than one LEDsmart+ device is connected in parallel, all these devices will now enter setup mode. The blink ON/OFF will also be see on all other LEDsmart+ devices connected in parallel

In the unlikely event that other LEDsmart+ devices connected in parallel do not enter setup, exit and try again.

Step 3

The timer is ready for the settings to be adjusted as required.  Go to the relevant setup function instructions

The hour timer allows a timeout duration of ¼ hour to 7½ hours in increments of ¼ hour.
Out of the box (factory defaults), the time out interval is set to ½ hour.
To change the time out interval from the default ½ hour, follow the steps below.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button twice

Step 3

LED will blink 2 times

Note: To cancel/exit do nothing for 30 seconds

Step 4

To set the time out interval, push and hold the button and count the number of blinks. Each blink of the indicator adds ¼ hour to the timer

Step 5

When the number of blinks counted is equivalent the total timeout period required, release the button
The time out interval is saved and setup will exit automatically

Note
– During normal use the indicator will blink when the timer is turned on to indicate it is in time out mode
– Trying to select a time interval of 0 will result in setting ½ hour timeout
– The timeout period on Hour Timers connected in parallel need to be set individually. The same timeout is not automatically set across units

The maximum brightness level provided by the timer can be set to suit customer requirements.
Note that when lamps are near to full brightness, it is difficult to see changes in dimming level. Therefore, when setting up maximum brightness, it is recommended that the lamp is slowly dimmed up to a point where no further changes in brightness can be seen, and the maximum level set at this point.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button three times

Step 3

Push the button to achieve the required maximum brightness level

Note: To cancel/exit do nothing for 30 seconds

Note: If more than one dimmer is connected to the same load, all dimmers connected to this load will now blink 3 times

Step 4

Adjust dial to required maximum brightness level

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

In the unlikely event that other LEDsmart+ devices connected in parallel do not enter setup, exit and try again.

The advanced timer mode provides an optional advanced warning to the user that the lights will shortly turn off automatically.
When the advance timer is enabled, at time out the lights are dimmed to 50% over a 4 second period and are held at this 50% level for 5 minutes. After this 5 minutes, the lights are turned off automatically.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button four times

Step 3

LED will blink 4 times

Note: To cancel/exit do nothing for 30 seconds

Step 4

To enable the advanced timer mode
Push and hold the button until the lamps(s) turn ON

To disable the advanced timer mode
Push and hold the button until the lamps(s) turn OFF (default)

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

Note that during this 5 minute warning period:-
• The LED indicators will blink at a faster rate
• A tap of the push button will restore the load to 100% ON and the timer will restart
• A long press of the push button will turn the load OFF.

When the timer is switched off, the white LED indicators in the timer can be set to glow or turn off.
By Default, the white LED indicators are set to glow when the timer is turned off.
To set the LED indicators to turn off when the timer is off, follow the steps below.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button 5 times

Step 3

The LED Indicator will blink 5 times

Note: To cancel/exit do nothing for 30 seconds

Step 4 

To set Indicator to glow on when timer is off
Push the button until the lamp(s) turns ON

To set Indicator to turn off when timer is off
Push the button until the lamp(s) turns OFF

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

If required, this hour timer can be converted to a standard LEDsmart minute timer, with a time out settable between 1 minute and 30 minutes, in 1 minute increments.
To convert to a minute timer, follow the steps below.

Step 1

Enter into the timer Setup Mode – See PART A

Step 2

Click the push button 6 times

Step 3

The LED Indicator will blink 6 times

Note: To cancel/exit do nothing for 30 seconds

Step 4

To change operation to hour timer mode

Push and hold the button until the lamps(s) turn ON (default)

To change operation to minute timer mode (Set minute timer mode)

Push and hold the button until the lamps(s) turn OFF

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

Step 1

Enter into the dimmer Setup Mode – See PART A

Step 2

Click the push button 8 times

Step 3

LED will blink 8 times

a.  If the MultiMate™ function is currently Disabled, lamp(s) connected to the dimmer will now turn OFF

b.  If the MultiMate™ function is currently Enabled, lamps(s) connected to the dimmer will now turn ON

Note: To cancel/exit do nothing for 30 seconds

Step 4

To Enable MultiMate™ (Default) push-and-hold the button until the lamp(s) turns ON

To Disable MultiMate™ a push-and-hold the button until the lamp(s) turns OFF

Note: To cancel/exit do nothing for 30 seconds

Step 5

Click once to save & exit

Step 1

Enter into the dimmer Setup Mode – See PART A

Step 2

Click the push button ten times

Step 3

The dimmer will automatically exit Setup Mode once reset